The SC(B)11‑13 series epoxy‑cast, non‑excited voltage‑regulating dry‑type transformers are manufactured using F‑class or H‑class epoxy resin compounds with fillers. After vacuum degassing via a thin‑film process, the windings—both high‑ and low‑voltage—are cast in thin layers under vacuum and pressure, with their inner and outer surfaces reinforced by glass‑fiber‑reinforced forming meshes. The result is a dry‑type transformer boasting exceptionally high mechanical strength, electrical insulation performance, and thermal resistance. It is an excellent solution for urban power‑grid upgrades and is particularly well suited for critical applications—such as high‑rise buildings, airports, power stations, and commercial centers—that demand fire‑proof, explosion‑proof, and moisture‑resistant operation.
 Product Features
  1. Flame-retardant, explosion-proof, pollution-free, maintenance-free, and capable of decentralized installation at the load center, thereby reducing capital investment and lowering costs.
  2. Low losses and excellent energy-saving performance deliver significant operational cost savings.
  3. Partial discharge level is less than 10 pC; the coil is non-hygroscopic and dust‑resistant, with high mechanical strength and excellent reliability, resulting in cost savings.
  4. Excellent short-circuit resistance and superior lightning‑impulse withstand capability.
  5. The enclosure is available in three materials—stainless steel, cold-rolled sheet, and aluminum alloy—and comes in two configurations: forced‑air cooling and natural heat dissipation. Cable entry and exit can be configured as top‑in/top‑out, bottom‑in/top‑out, or bottom‑in/bottom‑out.
  6. The transformer can be equipped with a temperature control and display system upon customer request, and it can be used in conjunction with a temperature control system.
Ordering Instructions
  When placing your order, please provide the following parameters:
  1. Product Model
  2. Rated Capacity
  3. Voltage Combination
  4. Scope of Adjustment
  5. Frequency
  6. Connection Group Designation
  7. Short-circuit impedance
  8. For products with special requirements, specify the technical specifications.

Technical Data Sheet for SC(B)12 Series 10 kV Three-Phase Resin-Insulated Dry-Type Distribution Transformers

Rated Rated voltage Connection No-load current (%) No-load loss (W) Load Loss (W) (75°C) Impedance Voltage (%)
   
Capacity Group
   
(kVA) High voltage (kV) Low voltage (kV)  
30 6 0.4 Yyn0 2 150 710 4
50     2 215 1000
±2×2.5% Dyn11  
    870
80 or   1.5 295 1380
100     1.5 320 1570
125 6.3   1.3 375 1850
160     1.3 430 2130
200 ±2×2.5%   1.1 495 2530
250     1.1 575 2760
315 or 10   1 705 3470
400     1 785 3990
500 ±2×2.5%   1 930 4880
630     0.85 1070 5880
630     0.85 1040 5960 6
800     0.85 1210 6960
1000     0.85 1410 8130
1250     0.85 1670 9690
1600     0.85 1960 11700
2000     0.7 2440 14400
2500     0.7 2880 17100
1600     0.85 1960 12900 8
2000     0.7 2440 15900
2500     0.7 2880 18800

Related products

Product Inquiry

If you have any needs, please feel free to contact us.
SAF Coolest v1.3.1.1 设置面板GAGSE-AGYF-JSAFE-ZFZ
图片ALT信息: Ming’an
违禁词: First, the best, top-tier, leading, one-of-a-kind, king, industry leader, pioneer, ultimate,

无数据提示

Sorry, this section is currently being updated. Please stay tuned!

You can view other sections or return to the previous page.Home

V1.3.1 SVG图标库请自行添加图标,用div包起来,并命名使用