SG(B)11 10kV (H)-Class Series Non-Encapsulated Dry-Type Distribution Transformer

Product Overview The SG(B)11 non‑encapsulated Class H dry-type power transformer employs an insulation system based on DuPont Nomex® paper. Both the high‑ and low‑voltage windings are insulated with Nomex® paper and undergo vacuum pressure impregnation with Class H solvent‑free insulating varnish, followed by high‑temperature curing. This process ensures excellent electrical and mechanical performance throughout the transformer’s entire service life. Product Features Nomex® paper exhibits excellent resistance to aging, shrinkage, and compression, while maintaining superior elasticity. As a result, even after years of operation, the windings retain their structural integrity and can withstand the mechanical forces generated during short circuits. The no‑load and load losses are 20% and 25% lower, respectively, compared to the requirements specified in GB 10228-1997, making this product a low‑loss, low‑noise, environmentally friendly solution. It is widely used in applications such as subways, high-rise buildings, mines, airports, and other environments characterized by high population density, stringent fire‑safety requirements, or harsh conditions involving humidity, high temperatures, and significant load fluctuations. Ordering Notes When placing your order, please provide the following parameters: 1. Product model number 2. Rated capacity 3. Voltage combination 4. Regulation range 5. Frequency 6. Connection group designation 7. Short-circuit impedance 8. Special technical requirements, if any SC(B)11 Series 10 kV (Class H) Non‑Encapsulated Distribution Transformer Technical Data Sheet Rated Rated Voltage Connection No-load Current (%) No-load Loss (W) Load Loss (W) (at 120°C) Impedance Voltage (%) Capacity Group (kVA) High Voltage (kV) Low Voltage (kV) 30 6 0.4 Yyn0 2 170 760 4 50 2 240 1070 ±2×2.5% Dyn11 870 80 or 1.5 330 1480 100 1.5 360 1690 125 6.3 1.3 420 1980 160 1.3 480 2280 200 ±2×2.5% 1.1 550 2710 250 1.1 640 2960 315 or 10 1 790 3730 400 1 880 4280 500 ±2×2.5% 1 1040 5230 630 0.85 1200 6290 630 0.85 1170 6400 800 0.85 1360 7460 1000 0.85 1590 8760 1250 0.85 1880 10500 1600 0.85 2200 12500 2000 0.7 2740 15500 2500 0.7 3240 18400 1600 0.85 2200 13900 8 2000 0.7 2740 17100 2500 0.7 3240 20200

Keywords:

SG(B)11 10kV (H)-Class Series Non-Encapsulated Dry-Type Distribution Transformer

Product Inquiry:

Product Description

Product Overview
The main insulation material of the SG(B)11 non‑encapsulated Class H dry‑type power transformer employs an insulation system based on DuPont Nomex® paper. Both the high‑ and low‑voltage windings are insulated with Nomex® paper and undergo vacuum pressure impregnation with a Class H solvent‑free insulating varnish, followed by high‑temperature curing. This process ensures that the transformer maintains excellent electrical and mechanical properties throughout its entire service life.
Product Features
Nomex paper exhibits excellent resistance to aging, shrinkage, and compression, coupled with exceptional elasticity. As a result, it ensures that even after several years of service, the transformer’s windings maintain a tightly structured configuration and can withstand the mechanical forces generated during short circuits. Its no-load and load losses are 20% and 25% lower, respectively, than the limits specified in GB 10228‑1997, making it a low‑loss, low‑noise, environmentally friendly product. This product is widely used in high‑density, fire‑safety‑critical environments such as subways, high‑rise buildings, mines, and airports, as well as in harsh conditions characterized by high humidity, elevated temperatures, and significant load fluctuations.

  Ordering Instructions
  When placing your order, please provide the following parameters:
  1. Product Model
  2. Rated Capacity
  3. Voltage Combination
  4. Scope of Adjustment
  5. Frequency
  6. Connection Group Designation
  7. Short-circuit impedance
  8. For products with special requirements, specify the technical specifications.

Technical Data Sheet for SC(B)11 Series 10 kV (H)-Class Non-Encapsulated Distribution Transformers

Rated Rated voltage Connection No-load current (%) No-load loss (W) Load loss (W) (120°C) Impedance Voltage (%)
  
Capacity Group
  
(kVA) High voltage (kV) Low voltage (kV)  
3060.4Yyn021707604
50  22401070
±2×2.5% Dyn11 
  870
80 or  1.53301480
100  1.53601690
1256.3 1.34201980
160  1.34802280
200 ±2×2.5%  1.15502710
250  1.16402960
315 or 10  17903730
400  18804280
500 ±2×2.5%  110405230
630  0.8512006290
630  0.85117064006
800  0.8513607460
1000  0.8515908760
1250  0.85188010500
1600  0.85220012500
2000  0.7274015500
2500  0.7324018400
1600  0.852200139008
2000  0.7274017100
2500  0.7324020200

Related products

Product Inquiry

If you have any needs, please feel free to contact us.
SAF Coolest v1.3.1.1 设置面板GAGSE-AGYF-JSAFE-ZFZ
图片ALT信息: Ming’an
违禁词: First, the best, top-tier, leading, one-of-a-kind, king, industry leader, pioneer, ultimate,

无数据提示

Sorry, this section is currently being updated. Please stay tuned!

You can view other sections or return to the previous page.Home

V1.3.1 SVG图标库请自行添加图标,用div包起来,并命名使用