S11-M·R Series 10 kV Class Wound-Core Power Transformer
Keywords:
S11-M·R Series 10 kV Class Wound-Core Power Transformer
Category:
Product Description
Overview
The S11-M.R three-phase, fully sealed distribution transformer features a core manufactured by specialized winding equipment that continuously coils silicon steel strips into a closed, monolithic structure. This design eliminates the seams and air gaps typical of conventional cores, significantly reducing noise levels. Following annealing treatment, the no-load losses are reduced by 30% compared to S9‑type models. The transformer employs a corrugated oil tank with a fully sealed construction, offering an attractive appearance, superior performance, and maintenance‑free operation, making it a next‑generation energy‑efficient and environmentally friendly product.
Product Features
1. The core is a seamless, non‑graded structure with an almost circular cross‑section, formed by winding silicon steel strip material. The yoke and core limbs are joined with rounded corners, and the core is of a closed configuration.
2. The high- and low-voltage windings are wound directly on the iron core, ensuring excellent concentricity between the two windings and superior short-circuit withstand capability.
3. Due to its unique core structure—formed by winding high‑quality, grain‑oriented cold‑rolled silicon steel sheets and subsequently annealed—the S11‑M.R transformer exhibits a 30% reduction in no‑load losses, a 70% reduction in no‑load current, and a noise level that is approximately 8 dB lower compared with an S9‑type transformer of the same capacity.
4. The oil conservator is eliminated, and a corrugated‑plate oil tank is adopted; temperature‑induced changes in oil volume are compensated by the elasticity of the corrugations, isolating the transformer oil from air and thereby extending its service life.
5. The corrugated oil tank features low temperature rise, a small footprint, and an aesthetically pleasing appearance.
6. All core‑processing operations have been fully mechanized, reducing labor intensity and improving product quality while ensuring consistent performance.
Technical Performance Parameters
|
Rated |
Rated voltage |
Connection |
No-load |
Loss (W) |
Impedance |
Reference external dimensions |
Reference weight |
Track gauge |
||||||
|
High pressure |
Low pressure |
No-load |
Load |
long |
wide |
High |
Body of the vessel |
Heavy oil |
Total weight |
|||||
|
30 |
6 |
0.4 |
Yyn0 |
1.5 |
100 |
630/600 |
4.0 |
1010 |
620 |
960 |
145 |
77 |
295 |
400×400 |
|
50 |
1.3 |
130 |
910/870 |
1060 |
630 |
1000 |
224 |
90 |
420 |
400×400 |
||||
|
63 |
1.2 |
150 |
1090/1040 |
1110 |
660 |
1080 |
240 |
95 |
460 |
400×400 |
||||
|
80 |
1.2 |
180 |
1310/1250 |
1135 |
660 |
1040 |
328 |
98 |
530 |
400×400 |
||||
|
100 |
1.0 |
200 |
1580/1500 |
1165 |
690 |
1085 |
325 |
125 |
575 |
400×400 |
||||
|
125 |
1.0 |
240 |
1890/1800 |
1185 |
700 |
1170 |
390 |
165 |
680 |
550×550 |
||||
|
160 |
1.0 |
280 |
2310/2200 |
1220 |
705 |
1190 |
499 |
147 |
840 |
550×550 |
||||
|
200 |
1.0 |
340 |
2730/2600 |
1280 |
725 |
1240 |
592 |
179 |
960 |
550×550 |
||||
|
250 |
0.9 |
400 |
3200/3050 |
1290 |
730 |
1260 |
724 |
191 |
1128 |
550×550 |
||||
|
315 |
0.9 |
480 |
3830/3650 |
1320 |
740 |
1320 |
712 |
196 |
1145 |
550×550 |
||||
|
400 |
0.8 |
570 |
4520/4300 |
1380 |
770 |
1380 |
953 |
237 |
1430 |
550×550 |
||||
|
500 |
0.8 |
680 |
5410/5150 |
1450 |
810 |
1430 |
1120 |
264 |
1690 |
660×660 |
||||
|
630 |
0.6 |
810 |
6200 |
4.5 |
1545 |
840 |
1445 |
1289 |
310 |
1960 |
660×660 |
|||
|
800 |
0.6 |
980 |
7500 |
1670 |
920 |
1535 |
1430 |
355 |
2350 |
820×820 |
||||
|
1000 |
0.6 |
1150 |
10300 |
1835 |
1090 |
1650 |
1796 |
450 |
2720 |
820×820 |
||||
|
1250 |
0.5 |
1360 |
12000 |
1901 |
1190 |
1675 |
2080 |
570 |
3300 |
820×820 |
||||
|
1600 |
0.5 |
1640 |
14500 |
1985 |
1210 |
1790 |
2300 |
645 |
3760 |
820×820 |
||||
|
2000 |
0.4 |
1940 |
18300 |
5.0 |
2140 |
1260 |
1910 |
3130 |
765 |
5145 |
820×820 |
|||
|
2500 |
0.4 |
2290 |
21200 |
2525 |
1480 |
2540 |
4198 |
925 |
6420 |
820×820 |
||||
|
Note: For three-phase transformers with a rated capacity of 500 kVA or less, the load loss values above the diagonal line in the table apply to the Dyn11 connection group, while the values below the diagonal line apply to other connection groups. |
||||||||||||||
Related products
Product Inquiry
Company Address: Hai’an Industry Park, Hai’an County, Jiangsu
Sales Hotline:0086-0513-88780188
After-sales service:0086-0513-88782288
Fax: 0086-0513-88782959
Postal code: 226600
Website:www.jsmadq.com
Email:jsmadq@sina.com 2930515310@qq.com
Scan to view the mobile version
无数据提示
Sorry, this section is currently being updated. Please stay tuned!
You can view other sections or return to the previous page.Home