D11-M·R Series 10 kV Single-Phase Wound-Core Power Transformer

This product complies with the national standards GB 1094 “Power Transformers” and JB/T 10317-2014 “Technical Parameters and Requirements for Single‑Phase Oil‑Immersed Distribution Transformers.” The D11‑M R‑10‑160/10 series is a single‑phase oil‑immersed distribution transformer featuring a rolled‑core design with a single‑frame, double‑column structure; the outer layers are spot‑welded rather than bound. High‑quality cold‑rolled silicon steel sheets are selected and cut on a high‑performance longitudinal slitting line, ensuring that burr heights are kept below 0.02 mm. Both the high‑ and low‑voltage windings are wound using premium oxygen‑free copper wire and advanced manufacturing processes. Thanks to the adoption of new materials, innovative manufacturing techniques, and state‑of‑the‑art production equipment, the transformer exhibits significantly reduced no‑load and load losses, with enhanced reliability and superior performance. It is a key new product currently being promoted nationwide.

Keywords:

D11-M·R Series 10 kV Single-Phase Wound-Core Power Transformer

Product Inquiry:

Product Description

  Overview

  This product complies with the national standards GB 1094 “Power Transformers” and JB/T 10317-2014 “Technical Parameters and Requirements for Single‑Phase Oil‑Immersed Distribution Transformers.” The D11‑M R‑10‑160/10 series is a single‑phase oil‑immersed distribution transformer featuring a wound‑core design with a single‑frame, double‑column structure; the outer layers are spot‑welded rather than bound. High‑quality cold‑rolled silicon steel sheets are employed and precision‑cut on a high‑performance slitting line, ensuring that burr heights remain below 0.02 mm. Both the high‑ and low‑voltage windings are wound using premium oxygen‑free copper wire and advanced manufacturing processes. Thanks to the adoption of new materials, innovative manufacturing techniques, and state‑of‑the‑art production equipment, the transformer exhibits significantly reduced no‑load and load losses, with enhanced reliability and superior performance. It is a key new product currently being promoted nationwide.

 

  Ordering Instructions

  When placing your order, please provide the following parameters:

  1. Product Model

  2. Rated Capacity

  3. Voltage Combination

  4. Scope of Adjustment

  5. Frequency

  6. Connection Group Designation

  7. Short-circuit impedance

  8. For products with special requirements, specify the technical specifications.

 

  Technical Performance Parameters

Rated capacity
Rated Power
(KVA)
Rated Voltage (kV)
Connection
Group
No-load
Electric current
(%)
Loss (W)
Impedance
Voltage
(%)
External dimensions (mm)
Weight (kg)
Track gauge
Horizontal × Vertical
(mm)
High pressure
(KV)
Low pressure
(KV)
No-load
Load
long
wide
High
Body of the vessel
Heavy oil
Total weight
10

6±2×2.5%

or 6.3 ± 2 × 2.5%

or 10 ± 2 × 2.5%

2×(0.22-0.24)

or 0.22–0.24

li0
2.0
50
240
3.5
800
620
920
100
40
210
210×210
20
1.8
70
375
830
630
960
120
50
270
270×270
30
1.7
85
490
850
630
1000
140
60
300
300×300
50
1.6
135
660
900
640
1040
190
75
350
350×350
63
1.5
160
790
940
650
1060
210
90
400
400×400
80
1.4
180
930
960
660
1080
230
100
460
460×460
100
1.3
210
1100
1000
700
1100
270
140
520
520×520
125
1.2
235
1300
1050
730
1130
300
160
580
580×580
160
1.0
270
1500
1100
780
1160
350
190
650
650×650

 

Related products

Product Inquiry

If you have any needs, please feel free to contact us.
SAF Coolest v1.3.1.1 设置面板GAGSE-AGYF-JSAFE-ZFZ
图片ALT信息: Ming’an
违禁词: First, the best, top-tier, leading, one-of-a-kind, king, industry leader, pioneer, ultimate,

无数据提示

Sorry, this section is currently being updated. Please stay tuned!

You can view other sections or return to the previous page.Home

V1.3.1 SVG图标库请自行添加图标,用div包起来,并命名使用