KYN28A-24 Type Armored Withdrawable AC Metal-Enclosed Switchgear

KYN28A-24 armored, withdrawable AC metal-clad switchgear (hereinafter referred to as the switchgear) is suitable for indoor three-phase power systems with a frequency of 50/60 Hz and a rated voltage of 24 kV. It is primarily used in power plants, substations, industrial and mining enterprises, and high-rise buildings for receiving and distributing electrical energy, as well as for circuit control, protection, and monitoring.

Keywords:

KYN28A-24 Type Armored Withdrawable AC Metal-Enclosed Switchgear

Product Inquiry:

Product Description

  Overview

  KYN28A-24 armored, withdrawable AC metal-clad switchgear (hereinafter referred to as the switchgear) is suitable for indoor three-phase power systems with a frequency of 50/60 Hz and a rated voltage of 24 kV. It is primarily used in power plants, substations, industrial and mining enterprises, and high-rise buildings for receiving and distributing electrical energy, as well as for circuit control, protection, and monitoring.

  The KYN28A-24 switchgear incorporates a range of features to prevent misoperation, including interlocks that prohibit moving the handcart under load, prevent closing the earthing switch when the circuit breaker is closed, block closing the earthing switch while energized, and guard against inadvertently entering an energized compartment. The KYN28A-24 switchgear is equipped with high‑performance VN2 or VS1 series center‑mounted high‑voltage AC vacuum circuit breakers and solid‑sealed pole vacuum switches. Its secondary circuits are fitted with advanced, reliable control and protection devices; the busbars employ heat‑shrink insulation or epoxy coating, with optimized electrode geometries, resulting in a compact cabinet design. The KYN28A-24 switchgear is a distribution device that combines cutting‑edge technology, stable performance, a well‑thought‑out structure, ease of operation, and proven safety and reliability.

 

  Product Reference Standards

  a) GB 1984 High-Voltage AC Circuit Breakers.

  b) GB 3906: AC metal-enclosed switchgear and control equipment, rated voltage 3.6–40.5 kV.

  c) GB/T 11022 Common Technical Requirements for High-Voltage Switchgear and Control Equipment.

  d) DL/T 404 Technical Requirements for Ordering Indoor AC High-Voltage Switchgear.

  e) DL/T 593 General Technical Specifications for Ordering High-Voltage Switchgear.

 

  Operating environmental conditions

  a. Ambient temperature: maximum temperature: +40°C; minimum temperature: -15°C; and the 24-hour average shall not exceed 35°C.

  b. The temperature conditions are as follows:

  --The daily average relative humidity shall not exceed 95%; the monthly average relative humidity shall not exceed 90%.

  --The average daily water vapor pressure does not exceed 2.2 kPa; the monthly average water vapor pressure does not exceed 1.8 kPa;

  Under such conditions, condensation may occasionally occur.

  c. Altitude not exceeding 1000 m;

  d. The surrounding air is not noticeably contaminated by dust, smoke, corrosive or flammable substances, vapors, or fumes;

  e. Vibrations or ground motions originating from outside the switchgear and control equipment may be disregarded;

  f. The amplitude of electromagnetic interference induced in the secondary system shall not exceed 1.6 kV.

 

  Technical Performance Parameters

Project Name
Unit
Parameter
Rated voltage
KV
24
Rated frequency
Hertz
50/60
Rated Insulation Level
1-minute power-frequency withstand voltage (RMS)
KV
Phase-to-phase and phase-to-ground
65
Quarantine
79
Lightning impulse withstand voltage (peak value)
125
fracture surface
145
Power-frequency withstand voltage of the auxiliary control circuit
V
2000
Rated current
A
630, 1250, 1600, 2000, 2500, 3150
Rated short-circuit breaking capacity
KA
20
31.5
Rated short-circuit making current (peak value)
KA
50
80
Rated short-time withstand current (4 s)
KA
20
31.5
Rated peak withstand current
KA
50
80
Rated voltage of the auxiliary control circuit
V
DC or AC 110/220
Protection rating
 
IP4X (circuit breaker compartment door open or isolating compartment IP2X)
External dimensions (width × depth × height)
mm
800*1810*2380
1000*1810*2380
Weight
kilogram
840-1440

 

  Ordering Instructions

  a) Main wiring diagram;

  b) Arrangement of switchgear and plan layout of the distribution room;

  c) The model, specifications, and quantity of the major electrical equipment within the switchgear;

  d) Secondary circuit diagram;

  e) When switchgear is to be used under special environmental conditions, this shall be specified at the time of order.

  f) Other special requirements.

Related products

Product Inquiry

If you have any needs, please feel free to contact us.