S11-DM Series (10 kV) Underground Transformer

Structure of Underground Transformers and Billboard‑Style Low‑Voltage Units: Underground transformers are divided into aboveground and underground sections. The main body is installed in a concrete pit, occupying no surface space. Both the transformer and its enclosure are equipped with high‑voltage bushings and low‑voltage terminals, high‑voltage load switches and backup fuses, plug‑in surge arresters, pressure relief valves, vacuum pressure gauges, temperature controllers, and oil level indicators—all accessible for observation and operation from ground level. The tank is fabricated from stainless steel, featuring a fully sealed design and a hermetically welded flange to minimize sealing surfaces, ensuring long‑term safe operation even in challenging underground environments. The aboveground portion of the underground transformer adopts a hybrid structure that integrates a billboard with a low‑voltage switchgear cabinet. Inside the enclosure is a low‑voltage distribution panel, while both sides serve as neon‑lit advertising billboards, suitable for public service announcements, traffic guidance, road information, and more, delivering striking visual impact. Employing underground transformers combined with this billboard‑style low‑voltage configuration aligns with urban ecological design principles, enhancing the urban landscape while minimizing land use. It is ideally suited for deployment along major city thoroughfares, at airports, on highways, and within residential neighborhoods.

Keywords:

S11-DM Series (10 kV) Underground Transformer

Product Inquiry:

Product Description

  Product Overview:


    Structure of Underground Transformers and Billboard‑Style Low‑Voltage Units: Underground transformers are divided into aboveground and underground sections. The main body is installed in a concrete pit, occupying no surface space. Both the transformer and its enclosure are equipped with high‑voltage bushings and low‑voltage terminals, high‑voltage load switches and backup fuses, plug‑in surge arresters, pressure relief valves, vacuum pressure gauges, temperature controllers, and oil level indicators—all accessible for observation and operation from ground level. The tank is fabricated from stainless steel, featuring a fully sealed design and a hermetically welded flange to minimize sealing surfaces, ensuring long‑term safe operation even in challenging underground environments. The aboveground portion of the underground transformer adopts a hybrid structure that integrates a billboard with a low‑voltage switchgear cabinet. Inside the enclosure is a low‑voltage distribution panel, while both sides serve as neon‑lit advertising billboards, suitable for public service announcements, traffic guidance, road information, and more, delivering striking visual impact. Employing underground transformers combined with billboard‑style low‑voltage units aligns with urban ecological design principles: they enhance the urban landscape, occupy minimal ground space, and are well suited for use along major city thoroughfares, at airports, on highways, and in residential neighborhoods.

Product Features:
  1. Suitable for urban environments (installable in basements or cellars), particularly well-suited to densely populated central cities.
  2. Suitable for lighting and power systems in streets, highways, bridges, tunnels, parking lots, airports, ports, tourist attractions, and more.
  3. The high- and low-voltage incoming and outgoing lines employ a fully sealed, fully insulated, and fully shielded wiring configuration.
  4. The enclosure is constructed from corrosion-resistant stainless steel, fully sealed, and can be immersed in water for a specified period.
  5. The protection system gives full consideration to ease of operation and safety, with components sourced from the U.S.-based COOPER company.
  6. The underground transformer is operated using an operating rod and features the same operating mode as a combined transformer.
  7. Taking into full account the specific thermal‑dissipation requirements, the transformer has been designed for low losses and low operating temperatures.
  8. Install waterproof ingress protection and automatic drainage measures inside the transformer vault.

 

 

  Ordering Instructions:
  When placing your order, please provide the following parameters:
  1. Product Model
  2. Rated Capacity
  3. Voltage Combination
  4. Scope of Adjustment
  5. Frequency
  6. Connection Group Designation
  7. Short-circuit impedance
  8. For products with special requirements, specify the technical specifications.

 

  Technical Data Sheet for the S11-DM Series (10 kV) Underground Transformer

Rated

Capacity

(kVA)

Rated voltage

Connection

Group

No-load current (%)

No-load loss (W)

Load loss (W)

Impedance Voltage (%)

High voltage (kV)

Low voltage (kV)

30

6

±2×2.5%

or

6.3

±2×2.5%

or 10

±2×2.5%

 

0.4

Yyn0

Dyn11

2.1

100

600/630

4

 

50

2.0

130

870/910

80

1.8

180

1250/1310

100

1.6

200

1500/1580

125

1.5

240

1800/1890

160

1.4

280

2200/2310

200

1.3

340

2600/2730

250

1.2

400

3050/3200

315

1.1

480

3650/3830

400

1.0

570

4300/4520

500

1.0

680

5150/5410

630

0.9

810

6200

4.5

800

0.8

980

7500

1000

0.7

1150

10300

1250

0.6

1360

12000

1600

0.6

1640

14500

2000

0.6

1960

17800

5.5

2500

0.5

2310

20700

Note: For transformers with a rated capacity of 500 kVA or less, the load loss values above the diagonal line in the table apply to the Yyn0 connection group, while those below the diagonal line apply to the Dyn11 connection group.

Related products

Product Inquiry

If you have any needs, please feel free to contact us.
SAF Coolest v1.3.1.1 设置面板GAGSE-AGYF-JSAFE-ZFZ
图片ALT信息: Ming’an
违禁词: First, the best, top-tier, leading, one-of-a-kind, king, industry leader, pioneer, ultimate,

无数据提示

Sorry, this section is currently being updated. Please stay tuned!

You can view other sections or return to the previous page.Home

V1.3.1 SVG图标库请自行添加图标,用div包起来,并命名使用