D11-M·R (10 kV) Series Single-Phase Oil-Immersed Wound-Core Distribution Transformer

This product complies with the national standards GB 1094 “Power Transformers” and JB/T 10317 “Technical Parameters and Requirements for Single-Phase Oil-Immersed Distribution Transformers.” The D11‑M·R series is a single-phase oil-immersed distribution transformer featuring a wound‑core design with a single-frame, double‑core‑column structure; the outermost layer is spot‑welded without additional binding. High‑quality cold‑rolled silicon steel sheets are selected and cut on a high‑performance longitudinal slitting line, ensuring that burr heights are kept below 0.02 mm. Both the high‑ and low‑voltage windings utilize premium oxygen‑free copper wire and are wound using advanced manufacturing processes. Thanks to the adoption of new materials, innovative processes, and state‑of‑the‑art production equipment, the transformer exhibits significantly reduced no‑load and load losses, with enhanced reliability and superior performance—making it a key product promoted nationwide.

Keywords:

D11-M·R (10 kV) Series Single-Phase Oil-Immersed Wound-Core Distribution Transformer

Product Inquiry:

Product Description

  Product Overview:


    This product complies with the national standards GB 1094 “Power Transformers” and JB/T 10317 “Technical Parameters and Requirements for Single-Phase Oil-Immersed Distribution Transformers.” The D11‑M·R series is a single-phase oil-immersed distribution transformer featuring a wound‑core design. Its core adopts a single‑frame, double‑column winding structure, with the outermost layers spot‑welded rather than bound. High‑quality cold‑rolled silicon steel sheets are selected and cut on a high‑performance slitting line, ensuring that burr heights remain below 0.02 mm. Both the high‑ and low‑voltage windings utilize premium oxygen‑free copper wire and are wound using advanced manufacturing processes. Thanks to the adoption of new materials, innovative techniques, and state‑of‑the‑art production equipment, the transformer exhibits significantly reduced no‑load and load losses, while its performance and structural integrity are markedly enhanced, making it a key product promoted nationwide.

  Ordering Instructions:
  When placing your order, please provide the following parameters:
  1. Product Model
  2. Rated Capacity
  3. Voltage Combination
  4. Scope of Adjustment
  5. Frequency
  6. Connection Group Designation
  7. Short-circuit impedance
  8. For products with special requirements, specify the technical specifications.

 

  Technical Data Sheet for the D11-M·R (10 kV) Series Single-Phase Oil-Immersed Wound-Core Distribution Transformer

Rated

Capacity

(kVA)

Rated voltage

Connection

Group

No-load current (%)

No-load loss (W)

Load loss (W)

Impedance Voltage (%)

High voltage (kV)

Low voltage (kV)

10

6

±2×2.5%

or

10

±2×2.5%

or 10

±2×2.5%

 

2×(0.22–0.24) or 0.22–0.24

Yyn0

Dyn11

2.0

50

240

3.5

 

20

1.8

70

375

30

1.7

85

490

50

1.6

135

660

63

1.5

160

790

80

1.4

180

930

100

1.3

210

1100

125

1.2

235

1300

160

1.0

270

1500

Related products

Product Inquiry

If you have any needs, please feel free to contact us.
SAF Coolest v1.3.1.1 设置面板GAGSE-AGYF-JSAFE-ZFZ
图片ALT信息: Ming’an
违禁词: First, the best, top-tier, leading, one-of-a-kind, king, industry leader, pioneer, ultimate,

无数据提示

Sorry, this section is currently being updated. Please stay tuned!

You can view other sections or return to the previous page.Home

V1.3.1 SVG图标库请自行添加图标,用div包起来,并命名使用